Aircon unit is Blinking Light

There are a few common scenario that will cause your air conditioning unit to switch off automatically:

  1. Aircon Unit is blinking light - This means there is an error in your AC system 
  2. Aircon Unit switch on, run for awhile and switch off automatically - This means your gas pipe thermistor might be faulty 
  3. Aircon Unit is overheated and cause the compressor to switch off - This means your outdoor unit is fully choke with dirt and cause it to overheat

Aircon is leaking water

If your air-conditioning system is leaking water, it could be cause by a few scenario,

Your aircon system has been in use for a few years,

  1. Drain pipe is choke with jelly and dirt thus causing back flow of condensate and dripping out of your aircon unit
  2. The indoor unit is so dirty that it chokes up the internal drain line and cause the blower to spit water out of your aircon unit
  3. There is icing forming on your indoor unit, causing water to drip. This is cause by low pressure of the system which has a possibility of gas leaking

Your aircon system is new and only has been in operation for a few months,

  1. There is insufficient gradient on your drain pipe, your installer might have install it wrongly.
  2. Your drain pipe is connected wrongly
  3. Your drain pipe has crack and causes a leak
  4. The drain pipe is not insulated and causes condensation at the bottom of your Indoor Unit

 


Aircon Pipe Leaking Gas

Most aircon leak are not easily detected as small pin needle leak will take a long time before you noticed it. Freon gas is odourless and is poisonous when you inhale in big quantity, it is always important to prevent it before it could get worst.

Below are the following symptoms you should take note.

  1. Loss of cooling power, you start to feel that your aircon is getting warmer day by day
  2. All your aircon indoor unit are not blowing out cold air
  3. Your coils are freezing and it causes water condensation which leaks from your indoor unit
  4. You have been topping up gas regularly because your aircon contractor told you that is normal. This is a false statement.
  5. If visual inspection is possible along the pipe routing, be sure to look out for stains as these are signs of a leak
  6. Lastly if the leaks is big, hear out for whistling sounds if any

Hoot smart monitoring device could also prevent this from happening. Contact us to find out more how you can implement this for your home and keep yourself safe!


Aircon Not Blowing Cold Air

When your aircon unit is not blowing out cold air, there might be a few causes.

  1. Weak airflow cause by dirty coil and blower that cannot generate enough cool air from the indoor unit
  2. If all aircon unit are not blowing out cold air, the compressor might be faulty or there is leak in your system
  3. If only one of your aircon unit is not cold, outdoor FCU thermistor sensor/expansion valve might be faulty.

No matter the cause, get it repaired by a professional aircon contractor to prevent worse aircon problems. Click on the whatsapp icon now to contact us!